We don't sell a fixed catalogue: every unit is defined to the project and manufactured under our brand at qualified partner factories. Our European range is specified to the applicable CE, IEC / EN 60076 and Ecodesign requirements. US 60 Hz projects are quoted separately against the utility specification; solar inverter and step-up integration is offered within the skid and containerised range.
Tell us the product, approximate rating and your e-mail. We will review the requirement and identify any missing information. For voltages, delivery country and project details, use the full configurator.
Fire safety for indoor and sensitive sites: data centers, public buildings. The core of our European offer.
Mineral oil or ester, from neighbourhood substations to industrial sites.
Compartmentalized transformer configured around the utility specification, installation and required documentation.
Transformer, MV switchgear and LV board integrated. Includes prefabricated compact substations (IEC 62271-202).
Assembled and tested in the factory, with optional inverter + step-up integration for solar plants.
Power transformer, HV switchgear and protection. Engineered to order, delivered turnkey.
| Power | Impedance | Behaviour classes | Indicative mass |
|---|---|---|---|
| 400 kVA | 6 % | F1 · E2 · C2 | ≈ 1.4 – 1.7 t |
| 630 kVA | 6 % | F1 · E2 · C2 | ≈ 1.9 – 2.3 t |
| 1,000 kVA | 6 % | F1 · E2 · C2 | ≈ 2.6 – 3.1 t |
| 1,600 kVA | 6 % | F1 · E2 · C2 | ≈ 3.6 – 4.2 t |
| Power | Impedance | Losses | Indicative mass | Indicative footprint |
|---|---|---|---|---|
| 400 kVA | 4 % | Tier 2 | ≈ 1.2 – 1.4 t | ≈ 1.45 × 0.95 m |
| 630 kVA | 4 % | Tier 2 | ≈ 1.6 – 1.9 t | ≈ 1.60 × 1.00 m |
| 1,000 kVA | 6 % | Tier 2 | ≈ 2.3 – 2.7 t | ≈ 1.80 × 1.10 m |
| 1,600 kVA | 6 % | Tier 2 | ≈ 3.4 – 3.9 t | ≈ 2.00 × 1.20 m |
| 2,500 kVA | 6 % | Tier 2 | ≈ 4.8 – 5.6 t | ≈ 2.30 × 1.40 m |
Basis: ONAN / AN, Dyn11, 50 Hz. Losses per EU Regulation 2019/1783 (Tier 2). Indicative pre-sizing values, exact masses and dimensions depend on manufacturer and options, confirmed at quotation.
| Range | Technology | Power | Voltage | Typical use |
|---|---|---|---|---|
| Cast resin (dry) | Dry, indoor | 100 – 3,150 kVA | ≤ 36 kV (MV) | Data centers, public buildings, sensitive sites |
| Oil-immersed distribution | Mineral oil / ester | 100 – 3,150 kVA | ≤ 36 kV (MV) | Grids, industry, outdoor substations |
| MV substation | Packaged, prefabricated | per transformer | ≤ 36 kV (MV) | Grid connection, industrial sites |
| Skid & containerised | Skid, container or e-house | per integrated transformer | ≤ 36 kV (MV) | BESS, solar, EV charging, sites, data centers |
| HV substation | Engineered-to-order | up to ~100 MVA | 36 – 170 kV (HV) | Renewables evacuation, large sites |
| US pad-mounted transformer | Compartmentalized, 60 Hz | Project-specific | Per utility specification | US distribution, commercial and industrial projects |
The stated NF EN, IEC and Ecodesign requirements apply to the European range. US-market transformers are quoted against the applicable project, utility and local requirements; the accepted standards, testing and documentation scope are stated in the quotation. Solar conversion integration is specified as part of the skid or containerised substation scope. See European compliance →
Indicative values, beyond these ranges, let's talk: send your specification.
Bushings, DGPT2, thermometers, gaskets, valves, breathers… to maintain your existing fleet, whatever the original brand.
See spare parts →Configure in minutes, or simply e-mail your own technical specification.
Configure a quote →